Your task is to design an environmental control system for a
Solution
Bleed air is the air extracted from one of the stages of compressor which can be used for either ECS aur domestic purppses. Bleed is generally taken from 2 stages of compressor, one for ground idle condition and other for cruise conditions.
For temperatures:
T1> T2: this is because temperature at location 1 is taken from stage 13 of compressor which has compressed the gas and has highr temperature. When this air passes through heat exchanger it would loose heat and hence T2 will be lower than T1.
T2>TA: this is because we are cooling bleed air with intake duct air. This intake duct has some diffusion while passing through intake duct hence its temperature will be higher than ambient air. When intake air duct temperature is higher than Ambient air, it can never cool any air to temperatures below ins own temperature. Hence T2will be higher than TA.
TB>TA: TV is the air which has been compressed due to ram effect hence it will have highr temperature than Ambient air.
Energy transfer = 156.63kj/kg
Q= mCpT
156.63=1*1.005*T
T=155.85°C
Hence T1= 175.85°C