LJ PIre Protection Plan Review 5 2 2 Quiz 1 2017 Using plot

LJ PIre Protection Plan Review 5 2 2 Quiz #1 2017 Using plot #3 be uilding. Show all calculations low, calculate the gross floor area of the ACME Engineers, Inc. 12.466 m Radius Fixed in place design drawing table 09144m 5494m Bookcase 10-91 8.7122 m 91 cm us Calculate Gross&Net; floor area ACME Engineers, Inc. t 15 24 m Typical extenor wall consists of 20 32 om CMU block with7 62 cm brick veneer tota thickness= 2794 on 31242m 12.7cm typ Pr 91 cm doors w panic 3 1242 m Chief Engineer Plot 3 Not to Scale (NTS)

Solution

GROSS FLOOR AREA.

Gross floor area includes the area of the inside perimeter of the exterior walls of the building under consideration, exclusive of vent shafts and courts, without deduction for corridors, stairways, closets, the thickness of interior walls, columns or other features.

gross area = 12.446*(15.24-0.2794) =186.19963 m2

 LJ PIre Protection Plan Review 5 2 2 Quiz #1 2017 Using plot #3 be uilding. Show all calculations low, calculate the gross floor area of the ACME Engineers, In

Get Help Now

Submit a Take Down Notice

Tutor
Tutor: Dr Jack
Most rated tutor on our site