Calculate the size of compressed air tank needed to run an experiment for 1 hour while maintaining at least 120 PSI tank pressure
Solution
The size of an air receiver can be calculated as follows: V= T x C x Pa/ (P1- P2)
Where, P1 is maximum operating pressure(PSI)
P2 is MIn. operating pressure(PSI)
T- total time of running(min)
C- Volumetric flow rate(cpm)
Pa-atm. pressure(14.5PSI)
Here C and P1 needs to be assume,
From STANDARD guidelines, Max. Operating pressure for SIngle stage compreesor is P1=1.10P2(for single stage compressor)
Here P1=132PSI
V=60 x C x 14.5/(132-120)
V=72.5 x C ft3........................C-Discharge ,cpm