1 Compute the load on column B3 contributed by this floor if

1. Compute the load on column B3 contributed by this floor if the floor live load is 150 psf. (Consider floor live-load reductions following provisions ASCE 7-16 as appropriate) Assume this is the uppermost floor in a multistory office building. Assume it has a one-way slab behavior. (2 points) 40ft

Solution

Since the live load exceeds 100 psf, it is not permitted to do live load reduction per ASCE 7-16.

Tributary width of column B3=(40/2)+(40/2)=40\'

Tributary length of column B3=(35/2)+(35/2)=35\'

Therefore, tributary area of column = 40*35=1400 sq ft

Load on column B3= 150*1400/1000=210 kips

 1. Compute the load on column B3 contributed by this floor if the floor live load is 150 psf. (Consider floor live-load reductions following provisions ASCE 7-