The following data has been obtained experimentally for a co
Solution
Following are the experimental test outcomes available with us for the specified composite specimen,
E1=156.403 MPa ( I suppose the material properties of E1 and E2 as MPa)
E2=27.786 MPa
v12=0.352
v21=0.016
G12=3.762
The type of composite specimen tested in lab is unidirectional carbon-epoxy composite, hence its behavior will be transversely isotropic in nature.
Transversely isotropic material is the one with physical properties which are symmetric about an axis that is normal to a plane of isotropy.
For validating the fundamental physical laws, following equations acts as restraints on values of elastic constants:
1. E1,E2,G12 > 0
E1=156.403>0, E2=7.786>0, G12=3.762>0
2. (1-v12*v21)>0
(1-(0.352*0.016))=0.995>0
Hence we can conclude that the outcomes of experimental test are physical in nature satisfying the required
restraints.