ACME Refrigerator Co has claimed that a new model freezer op
ACME Refrigerator Co. has claimed that a new model freezer operates using 310 W of power, has an internal temperature of 260 K (TL), and rejects 510 W (QH) of heat to an environment at 635 K (TH).
1. Calculate the heat rate (QL) that the refrigerator receives from the cold storage.
2. Calculate the coefficient of performance (COP) of this refrigerator.
3. Calculate the ideal COP of a refrigerator operating between the given TH and TL.
4. Is the manufacturer’s claim valid? Why or why not?
Solution
>> Now, Tl = 260 K
Th = 635 K
Qh = 510 W = Heat supplied to higher temperature body
and, W = Power required = 310 W
So, Heat Rate, Ql = Qh - W = 510 - 310 = 200 W ......Heat refrigerator recieves fro the storage.....
2). As, COP = Ql/W = 200/310 = 0.645
3). Ideally, COP = Ql/W = Tl/(Th - Tl) = 260/(635 - 260) = 0.6933
4). As, COP of given refrigerator is less than Maximum COP (or Canot Refrigerator COP), So, manufacturer\'s claim is valid .........