In manufacturing the special coaling on a curved solar absor
Solution
SOLUTION:
1) here areaA1 of heater is intercepted by absorber area A2 and wall area 2*A3,hence shape factor are as per enclosure thereom
f12+f13=1
f21+f23=1
2) hence here by geometry we have
total area intercepted isA=A2+2*A3=15+L*H*2=15+2*10*1=35
hence area intercepted by absorber is=A2/A=15/35=.4285
for wall=A3*2/A=20/35=.5715
3) for reciprocal thereom
F12*A1=F21*A2
F21=.2856
F23=1-.2856=.7143
4)here heat transfer between two gray bodies is
Q12=5.67*10^-8*(T1^4-T2^4)/((1-e1/e1*A1)+(1/a1*F12)+(1-e2/e2*A2))
e1=.9 and e2=.5
on solving A1=10*1=10 m2
on solving we get
Q12=158610.57 W/m2
4) heat rejected to surrounding wall by absorber is
Q23=5.67*10^-8*(T2^4-T3^4)/((1-e2/e2*A2)+(1/A2*F23)+(1/A2))
on solving we get
Q23=-32805.29 W/m2
5) net heat transfer for absorber is
Q2=Q12-Q23=158610.57-2*32805.29=92999.99 W/m2