Using Swagelok Valve Sizing Technical Bulletin calculate air
Using Swagelok Valve Sizing Technical Bulletin: calculate air pressure drop across a valve with C_v=0.001 if the flow rate is 0.2 sefm. The inlet pressure is 1000 psig.
Solution
Enter the vertical scale with the inlet pressure at the valve (p1 = 1000 psig).
Read across to the desired flow rate (q = 0.2 std ft3/min).
The diagonal line is the desired Cv value (Cv = 0.0010).