A pump is located 45 m to one side of and 35 m above a reser
A pump is located 4.5 m to one side of, and 3.5 m above, a reservoir. The pump is designed for a flow rate of 6 L/s. For satisfactory operation, the static pressure at the pump inlet must not be lower than -6 m of water gage (note, this is like mm of water for pressure, just in meters). Determine the smallest standard commercial steel pipe that will give the required performance.
Solution
Please refer following chegg link:
http://www.chegg.com/homework-help/pump-located-45-m-one-side-35-m-reservoir-pump-designed-flow-chapter-8-problem-143p-solution-9780471742999-exc