The objective of this is to design a steam power cycle and d
Solution
solution:
1)here pump entry temperature is 283 k hence enthalphy
h1=hf1=42 kj/kg
2)thermal efficiency is given by
n=W/Qs
W=20000 kw
n=.35
Qs=heat supply=57142.85 kw
Qs=W+Qr
Qr=37142.85 kw
where heat rejected=heat taken by cooling water
To=293 k
Ti=283 k
Qr=mcw*Cpw*(To-Ti)
Cpw=4.187
mcw=887.09 kg/s
3)here we select pump to be MMK with flow rate upto 75 m3/hr
hence Pb=130 bar
Pc=.01227 bar
hence pump work=h2\'-h1=(Pb-Pc)/10*np=15.292 kj/kg
hence h2\'=57.292 kj/kg and T2\'=10.75 c or 283.75 k
here h4 for x=.9
h4=h1f+.9hfg1=42+.9*2477.8=2272.02
Qr=m(h1-h4)
m=16.65 kg/s
Q=59.94 m3/hr hence pump selected is correct as MMK
here for pump mass flow rate selected for x=.9 steam quality is 16.65 kg/s and hence we continue with same mass flow rate
4)here we select turbine DYR with Wt=40200 kw
Wta=40200/.9=44600 kw
here for heat supplied for same flow arte is
Qs=m(h3-h2)=57142.85 kw
h3=3489.29 kj/kg
where for h3=3489.29 and Pb=130 bar
T3=830 k
here turbine work is
Wt=Wn+Wp=20000+16.65*15.292=20254.61 kw
in this way for rankine cycle efficiency of 35% we get that
T1=T4=283 k
T2\'=283.75 k
T3=830 k
Pb=130 bar
Pc=.01227 bar
m=16.65 kg/s
x=.9
mcw=887.09 kg/s
Ti=283 k and To=293 k
9)in above design power produced due to efficiency is not accounted and hence we have to increase mass flow rate to increase turbi work ,so repeated calculation areas follows
10)here for selected pump we have pressure limit as
Pc=.01237 bar
Pb=130 bar
hence pump work=(Pb-Pc/10)*(1/np)
so we get that
Wp=15.292 kj/kg
11)here at inlet temperarature is
T1=10 Cor 283 k
h1=42 kj/kg
hence h2\'-h1=Wp
we get that
h2\'=57.29 kj/kg
12)where condition at exit steam condition at exit
x=.9
h4=h1+x(hfg)
hfg=2477.87
so we get h4
h4=2272.02 kj/kg
13)here tutbine work require is
we select mass flow rate by trial and error to be m=18.5064 kg/s
Wt=(20000/.9)+m*Wp=22505.22kw
hence for thermal efficiency n=.35
heat supplied
n=Ws/Qs
Ws=Wt-m*Wp=22222.22 kw
Qs=63492.06 kw
hence heat rejected=Qr=Qs-Ws=41269.84 kw
14)hence available equtaionare
m*(h2\'-h1)=282.99 kw
m(h3-h2\')=63492.06 kw
m(h3-h4)=22505.22 kw
m(h4-h1)=41269.84 kw
first two equation and last two equation are giving equal value hence balanced condition of system
from second equation
m(h3-h2\')=63492.06
h3=3430.81+57.292=3488.10 kj/kg
from third equation as
m(h3-h4)=22505.22
h3=3488.09 lj/kg
15)here for
h2\'=57.292 kj/kg and Pb=130 bar T2=10.75 c
for h3=3488.09 kj/lg ,Pb=130 bar,T3=830 k
16)here mass flow rate of cold water is given by
Qr=mcw*Cpw(To-Ti)
To=20c and Ti=10 C
41269.84=mcw*4.187*10
mcw=985.66 kg/s
and such high flow rate will beachieve by increasing tube of condenser heat exchanger
17)in thisway we get net power output to be completely W=20 MW and output quality as x=.9