Question 3 A 12 inch diameter wellis installed in a confined
Question 3: A 12 inch diameter wellis installed in a confined aquifer with a saturated thickness of 100 feet. The aquifer has a transmissivity of 40,000 gpd/ft. Compute the drawdown at wells that are located 0.5 ft and 400 ft from the pumping well 1 year after pumping at a rate of 600 gpm.
Solution
Solution:-
Given
Q = 600 gpm = 864*103 gpd
Let Storage coefficient(S) = 0.004
T = 40000 gpd/ft
Time (t) = 1 year = 365 days
Let drawdown = s
Case 1
When r = 0.5 ft
We know that
s = Q/(4?T) *(log(4Tt/(r2S)) - 0.5772)
s = 864*103/(4?*40000) * (log(4*40000*365/(.52*0.004)) – 0.5772)
s = 17.5 feet Answer
Case 2
When r = 400 feet
Draw down(s) = 864*103/(4?*40000)*(log(4*40000*365/(4002*0.004)) – 0.5772)
Draw down(s) = 7.53 feet Answer