Thermocouple are divided into types based on construction an
     Thermocouple are divided into types based on construction and operating conditions, of which the most common is the Type K thermocouple. Values of the thermoelectric voltage for any measured temperature can be looked up in standard tables constructed by NIST.  Find the expected voltage for a K-type thermocouple reading a temperature of 112 degree C. Cite your data table source. 
  
  Solution
the table used is http://www.omega.com/temperature/Z/pdf/z204-206.pdf
using interploation the voltage at 112 degree celcius is 4.5912 mV