Question 1 All pressure measurements are made against a refe
Question 1
All pressure measurements are made against a reference pressure. The reference pressure for psig is _____.
a. a vacuum
b. atmospheric pressure
c. 0 inches of water column
d. 100 inches of water column
Question 2
If none of the detectors in a level measurement system are in contact with the measurement material, the system is described as _____.
a. displacing
b. inferential
c. noninvasive
d. resistive
Question 3
A barometer reading can be taken from a liquid column gauge.
a. True
b. False
Question 4
A compressor in a refrigerator converts a freon gas into a liquid.
a. True
b. False
Question 5
A rotameter can be used to provide a feedback signal for closed-loop control.
a. True
b. False
Question 6
Flow rates of solids are determined by measuring the weight on a specified length of a conveyer belt during a given time period.
a. True
b. False
Question 7
With an ultrasonic sensor, _____ is developed at its output when it measures the minimum level.
a. 0 mA
b. 4 mA
c. 10 mA
d. 20 mA
Question 8
The unit of measure which represents viscosity is called the _____.
a. centimeter
b. poise
c. density
d. weight
Question 9
If a liquid is removed from an enclosed container, the pressure on _____.
a. the inside wall of the container is less than the pressure exerted on the outside wall
b. the inside wall of the container is more than the pressure exerted on the outside wall
c. both sides of the container\'s walls will remain the same
Question 10
A _____ is capable of accurately measuring temperatures from a distance.
a. RTD
b. thermistor
c. thermocouple
d. pyrometer
Question 11
Molecular movement stops when _____ is reached.
a. 0 degrees C
b. 0 degrees F
c. absolute zero
d. none of the above
Question 12
In a differential pressure flow meter, the velocity of a fluid leaving the orifice plate is _____ the fluid that approaches it.
a. less than
b. greater than
c. the same as
Question 13
A pyrometer that measures radiant energy at two different wavelengths is the _____ pyrometer.
a. broadband
b. optical
c. ratio
d. dual color
Question 14
Positive displacement flow meters are physically rotated by the fluid to develop the readings.
a. True
b. False
Question 15
When a pressure transducer is connected to the bottom of a vessel for the purpose of measuring level, what is the actual variable being measured?
a. level, directly
b. differential pressure
c. hydrostatic head pressure
d. volume
Question 16
Pressure is measured as a force per unit of _____.
a. volume
b. time
c. area
d. mass
Question 17
The method of measuring one variable to determine the value of another is referred to as _____.
a. the conversion method
b. an inferred measurement
c. a translation measurement
Question 18
_____ are classified as fluids.
a. Liquids
b. Gasses
c. Vapors
d. All of the above
Question 19
The level of a material can be determined by measuring the weight of the contents in a pressurized container.
a. True
b. False
Question 20
An increased thermocouple output voltage can be obtained by wiring two or more thermocouples in parallel.
a. True
b. False
Question 21
There are _____ resistive pressure elements in the bridge circuit of a semiconductor strain gauge.
a. 1
b. 2
c. 3
d. 4
Question 22
Which of the following terms identify the unit of measurement for flow?
a. velocity
b. differential pressure
c. volumetric flow rate
Question 23
The low atmospheric pressure that exists on a stormy day will have a different effect on an open container hydrostatic pressure reading than when a high atmospheric pressure exists on a clear day.
a. True
b. False
Question 24
The term _____ is commonly used to describe the height of a liquid in a container above the measuring point.
a. specific gravity
b. head
c. atmosphere
d. density
Question 25
The _____ type of flow meter is the most common type of meter to measure the volume of fluid that flows.
a. differential pressure
b. positive displacement
c. velocity
Question 26
Solids that float on liquids are referred to as _____.
a. foam
b. buoyants
c. slurry
d. contaminants
Question 27
A rodgauge provides an inferred measurement for level.
a. True
b. False
Question 28
A gas can be a vapor, steam, or air from the atmosphere.
a. True
b. False
Question 29
In thermocouple circuits, cold junction compensation is used to eliminate error due to the effects of _____.
a. hysteresis
b. dead band
c. ambient temperature
d. open circuits
Question 30
The process by which thermal energy is transferred by a solid is called _____.
a. convection
b. conductance
c. radiation
Solution
1 b
2b
3a
4b
8b
10d
11c
12b
14a
15c
16c
18d
22b
24b
25a
26b
28b
30b
above answers are right but which i have left them because am not sure