A pharmacological manufacturer is concerned that a new drug
A pharmacological manufacturer is concerned that a new drug used to control hypertension may alter fasting blood glucose (FBG). What sample size would he or she need in a randomized clinical trial (equal numbers of subjects given the new drug or placebo) to have 80% power to detect a 5 point difference in FBG if the standard deviation of FBG in the population is 19?
Solution
Compute Sample Size
 n = (Z a/2 * S.D / ME ) ^2
 Z/2 at 0.2% LOS is = 1.28 ( From Standard Normal Table )
 Standard Deviation ( S.D) = 19
 ME =5
 n = ( 1.28*19/5) ^2
 = (24.32/5 ) ^2
 = 23.658 ~ 24      