3. What is synchronous reactance?
Solution
synchronous reactance is a combination of armature winding leakage reactance and a reactance used to represent armature reaction. The synchronous machine tests give the induced voltage and the current when armature reaction is greatest, for a range of field current values. This data can be used to approximate the synchronous reactance of the machine.